Expansion
Valves
Expansion
valves are devices used to control the refrigerant flow in a refrigeration
system. They help to facilitate the change of higher pressure of liquid
refrigerant in the condensing unit to lower pressure gas refrigerant in the
evaporator.
The
term "low side" is used to indicate the part of the system that
operates under low pressure, in this case the evaporator. The "high
side" is used to indicate the part of the system that operates under high
pressure, in this case the condenser.
Types of Expansion Valves
There are basically four types of
valves that are in used. These valves are also refer to as metering devices.
- Automatic
Exp. Valves
- Thermostatic
Exp. Valves
- Capillary
Tubes
- Float Valves
Automatic Expansion Valve regulates the flow of
refrigerant from the liquid line to the evaporator by using a pressure-actuated
diaphragm. It maintains a constant pressure in the evaporator.
The setback is that it is not
efficient if the load fluctuates hence this type is not suitable for use in air
conditioning as the load fluctuates a lot during its operation.
Thermostatic Expansion Valve uses a valve mechanism to
control the flow of liquid refrigerant into the evaporator coil. The flow is
controlled by the pressure in the evaporator.
This type of metering device is able
to operate well when the load fluctuates and hence is suitable for use in air
conditioning system. When the evaporator warms, the valve provides a higher
flow rate amd when it cools, it reduces the flow rate.
It is also commonly refer to as TXV,
TEV or TX valve. There is a sensing bulb which detects the temperature of the
coil and is usually located at a higher temperature within the evaporator.
The bulb must be clamped firmly to
the coil to ensure proper sensing. When the temperature of the evaporator
increases due to the demand for cooling, the pressure in the bulb will also
increase hence pushing the spring to open the valve.
Similarly, when the temperature of
the evaporator reduces due to a lack of demand for cooling, the pressure in the
bulb will drop hence causing the spring to close the valve.
Capillary Tube is a tube with small internal
diameter and could be coiled for part of its length. It is installed to the
suction line. A filter-drier is sometimes fitted before the tube to remove dirt
or moisture from the refrigerant.
This device is simple, does not have
any moving part and lasts longer. In order to use this device, the amount of
refrigerant in the system must be properly calibrated at factory level.
Due to its lower cost compared to TXV, this metering device is used in units that are produced in large quantity such as room or window air conditioners.
Due to its lower cost compared to TXV, this metering device is used in units that are produced in large quantity such as room or window air conditioners.
Depending on the capacity design of
the system, the capillary tube internal diameter that is commonly used range
from 0.031" to 0.065" and the outer diameter from 0.083" to
0.130".
Float Valve is actuated by a float that is
immersed in the liquid refrigerant. Both low-side float and high side-float are
used to control the flow of liquid refrigerant.
The low-side float helps to maintain
a constant level of liquid refrigerant in the evaporator. It opens when there
is no liquid in the evap. and closes when there is liquid in the evap.
The high-side float is located at the high pressure side of the system and maintain a constant level of refrigerant in the condenser. When the compressor operates, the condensed refrigerant flows to the float chamber and opens the valve.
The high-side float is located at the high pressure side of the system and maintain a constant level of refrigerant in the condenser. When the compressor operates, the condensed refrigerant flows to the float chamber and opens the valve.
This causes the refrigerant to flow
into the evaporator where it is stored. As the liquid level falls in the float
chamber, the valve opening will close hence preventing the liquid from flowing
to the evap.